Search

Search for "shaft" and "generator"

Displaying results 1 to 20 out of 30


Asynchronous generators

100%

Asynchronous generators Three-phase asynchronous generators Asynchronous generators are used to recover braking energy back into the ... this. In order to generate energy, the asynchronous generator requires a supply network (grid-excited asynchronous generator) or a parallel-connected capacitor bank in isolated operation (capacitor-excited or self-excited asynchronous

Size: 33 K - Created: 07-05-12 - Modified: 20-01-17 09:46
Path: /Products/Three-phase generators/Asynchronous generators

Synchronous generators

100%

Synchronous generators Three-phase synchronous generators The brushless, electronically controlled version of the AEM synchronous generator with integrated AEM voltage regulator (AVR) meets the ... systems and the power supply of test facilities. Shaft height: up to 800 Protection degree: up to IP 44 ... on application of load regulator tailored to AEM

Size: 31 K - Created: 07-05-12 - Modified: 07-09-17 09:55
Path: /Products/Three-phase generators/Synchronous generators

Horster Mühle power plant, Germany

85%

... of the Ruhr. In order to increase production, the asynchronous generators were replaced by four AEM synchronous generators. This allowed power plant performance to be increased by 20-30%. Technical data . SE 500 S10 + Type SE 500 S10 Number of units 4 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated ... Rated power [kVA] 500 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 18.5 K - Created: 06-09-13 - Modified: 12-09-16 13:32
Path: /References/Hydropower/Horster Mühle power plant, Germany

Viking Legend River Cruise Ship

82%

... Legend” is equipped with 3 three-phase asynchronous generators and 6 three-phase asynchronous motors. Two AH 400 M4 generators coupled with diesel motors allow for the operation ... thruster drives via converters. The third AH LL4 315 generator is also coupled with a separate diesel motor and ... 350 Rated voltage [V] 690 Rated frequency [Hz] 60

Size: 24 K - Created: 15-02-13 - Modified: 10-10-17 14:23
Path: /References/Ship & Offshore/Viking Legend River Cruise Ship

Viking Prestige River Cruise Ship

81%

... is used in the sequel constructions. Our three-phase generators, coupled with a diesel motor, assume the power ... 315 Rated voltage [V] 690 Rated frequency [Hz] 60 Shaft height [mm] 315 Mounting IM B3 + Type AH 315 L6 ... 340 Rated voltage [V] 690 Rated frequency [Hz] 60 Shaft height [mm] 315 Mounting IM B3 + Type SE 315 LL4 Number of units 2 Machine type

Size: 24 K - Created: 19-02-13 - Modified: 10-10-17 14:40
Path: /References/Ship & Offshore/Viking Prestige River Cruise Ship

Eckhart power plant, Austria

81%

... has now become a tourist destination thanks to its architectural features. An AEM synchronous generator is driven by a Kaplan turbine via a low-noise belt. Technical data . SE 500 S14 + Type SE 500 S14 Number of units 1 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated speed [rpm] 429 Rated power [kVA] 450 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 18.4 K - Created: 06-09-13 - Modified: 14-02-17 10:57
Path: /References/Hydropower/Eckhart power plant, Austria

Greitherbach power plant, Austria

81%

... was restored in 2006 and now runs at five times the performance thanks to the use of an AEM generator. Technical data . SE 400 M8 + Type SE 400 M8 Number of units 1 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated speed [rpm] 750 Rated power [kVA] 300 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 18.5 K - Created: 06-09-13 - Modified: 12-09-16 13:41
Path: /References/Hydropower/Greitherbach power plant, Austria

Luxury cruise ship Crystal Bach

81%

... drive systems with a total of four AEM generators. For the first time, we supplied our generators with permanent-magnet excitation devices. In the ... the inverters with energy so that they start the generators and thus generate current for the start-up of the motors. The generators operate with two maximum speeds. In normal operation ... 340 Rated voltage [V] 690 Rated frequency [Hz] 60

Size: 21 K - Created: 26-09-17 - Modified: 12-10-17 08:35
Path: /References/Ship & Offshore/Luxury cruise ship Crystal Bach

MV Orion Expedition Cruise Ship

81%

... L4 + Type SE 400 M4 Number of units 1 Machine type generator, motor / synchronous Degree of protection IP 23 ... 750 Rated voltage [V] 400 Rated frequency [Hz] 50 Shaft height [mm] 400 Mounting IM B3 Type SE 400 L4 Number of units 2 Machine type generator / synchronous Degree of protection IP 23 Cooling ... 1.000 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 21 K - Created: 13-02-13 - Modified: 12-09-16 12:13
Path: /References/Ship & Offshore/MV Orion Expedition Cruise Ship

MS Schleswig-Holstein Double-Ended Ferry

81%

... power supply aboard the MS Schleswig-Holstein is ensured by two of our SE 315 S4 synchronous generators. Technical data . SE 315 S4 + Type SE 315 S4 Number of units 2 Machine type generator / synchronous Degree of protection IP 23 Cooling system IC 01 Rated speed [rpm] 1.500 Rated power [kVA] 250 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 18.8 K - Created: 14-02-13 - Modified: 12-09-16 11:50
Path: /References/Ship & Offshore/MS Schleswig-Holstein Double-Ended Ferry

Moggio power plant, Italy

80%

... flows through a perfectly restored forge. A Pelton turbine drives a vertical synchronous generator manufactured by AEM. The standard capacity is 1.9 GWh. Technical data . SE 630 S12 + Type SE 630 S12 Number of units 1 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated speed [rpm] 500 Rated power [kVA] 1.050 Rated voltage [V] 690 Rated frequency [Hz] 50

Size: 18.4 K - Created: 05-09-13 - Modified: 12-09-16 14:06
Path: /References/Hydropower/Moggio power plant, Italy

E. R. Elsfleth Container Ship

80%

... 710 M10 . SE 315 M4 + Type SE 710 M10 Number of units 3 Machine type generator / synchronous Degree of protection IP 23 Cooling system IC 01 Rated ... power [kVA] 2.780 Rated voltage [V] 450 Rated frequency [Hz] 60 Shaft height [mm] 710 Mounting IM B20 + Type SE 315 M4 Number of units 1 Machine type

Size: 20 K - Created: 26-04-13 - Modified: 26-09-17 08:58
Path: /References/Ship & Offshore/E. R. Elsfleth Container Ship

Isenthal power plant, Switzerland

80%

... transported to the power plant. The power plant is also home to an AEM vertical synchronous generator which is in use between the twin Pelton turbines. Technical data . SF 630 S6 + Type SF 630 S6 Number of units 1 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated speed [rpm] 1.000 Rated power [kVA] 2.100 Rated voltage [V] 950 Rated frequency [Hz] 50

Size: 18.5 K - Created: 06-09-13 - Modified: 12-09-16 14:00
Path: /References/Hydropower/Isenthal power plant, Switzerland

Vordernbergerbach power plant, Austria

80%

... In the plant, the impeller of the cross-flow turbine is connected to the AEM synchronous generator via a gearbox. Each year, the around 2.3 GWh of electricity yield is generated using a 320 kW machine. Technical data . SE 400 S6 + Type SE 400 S6 Number of units 1 Machine type generator / synchronous Degree of  protection IP 23 Cooling sytem IC 01 Rated speed [rpm] 1.000 Rated power [kVA] 324 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 18.7 K - Created: 05-09-13 - Modified: 12-09-16 13:37
Path: /References/Hydropower/Vordernbergerbach power plant, Austria

Turrachbach power plant, Austria

80%

... completely energy self-sufficient by 2015. Around 5.4 GWh are generated using a synchronous generator from AEM Dessau, which is driven by a cross-flow turbine. Technical data . SE 630 M6 + Type SE 630 M6 Number of units 1 Machine type generator / synchronous Degree of protection IP 44 Cooling system IC 81W Rated speed [rpm] 1.000 Rated power [kVA] 2.029 Rated voltage [V] 690 Rated frequency [Hz] 50

Size: 18.6 K - Created: 25-04-13 - Modified: 12-09-16 13:57
Path: /References/Hydropower/Turrachbach power plant, Austria

MS Deutschland luxury cruise liner

80%

... The power supply aboard the MS Deutschland is ensured by two of our SE 500 L8 synchronous generators. Technical data . SE 500 L8 + Type SE 500 L8 Number of units 2 Machine type generator / synchronous Degree of protection IP 44 Cooling system IC 81W Rated speed [rpm] 900 Rated power [kVA] 1.800 Rated voltage [V] 690 Rated frequency [Hz] 60

Size: 18.7 K - Created: 24-03-13 - Modified: 12-09-16 12:18
Path: /References/Ship & Offshore/MS Deutschland luxury cruise liner

Quantum of the Seas Cruise liner

79%

... New York 4,100 passengers go on a cruise to the Caribbean, Bahamas and Bermudas. Two diesel generators of type SE 500 M4 provide the electricity on board. Technical data . SE 500 M4 + Type SE 500 M4 Number of units 2 Machine type generator / synchronous Degree of protection IP 23 Cooling system IC 01 Rated speed [rpm] 1,800 Rated power [kVA] 2,662 Rated voltage [V] 690 Rated frequency [Hz] 60

Size: 18.7 K - Created: 26-11-14 - Modified: 12-09-16 12:50
Path: /References/Ship & Offshore/Quantum of the Seas Cruise liner

Test Stand Machines

79%

... S4 + Type AH 355 M4 Number of units 1 Machine type generator / asynchronous Degree of protection IP 23 Cooling ... 604 Rated voltage [V] 670 Rated frequency [Hz] 50 Shaft height [mm] 355 Mounting IM B3T Rotor type ... 1,500 Rated voltage [V] 936 Rated frequency [Hz] 50 Shaft height [mm] 450 Mounting IM B3 Rotor type squirrel-cage rotor + Type RH 400 S4 Number of units 1 Machine type

Size: 25 K - Created: 04-11-12 - Modified: 12-09-16 16:55
Path: /References/Industrial Systems/Test Stand Machines

Ship & Offshore

78%

... motor plant in Dessau has been making motors and generators for the shipbuilding industry for more than 35 years. We thus have unique industry expertise. Shaft generators and auxiliary diesel generators for energy supply In addition to our three-phase generators for auxiliary diesel generators, our product range also includes

Size: 43 K - Created: 07-05-12 - Modified: 23-06-23 12:23
Path: /References/Ship & Offshore

Rothorn Container Ship

78%

... dwt and a loading capacity of 1,122 TEUs (20-foot ISO containers). Technical data . SE 450 S4 + Type SE 450 S4 Number of units 1 Machine type generator / synchronous Degree of protection IP 23 Cooling system IC 01 Rated speed [rpm] 1.800 Rated power [kVA] 1.250 Rated voltage [V] 450 Rated frequency [Hz] 60

Size: 18.3 K - Created: 26-04-13 - Modified: 12-09-16 12:15
Path: /References/Ship & Offshore/Rothorn Container Ship

Weser Pilot Station Ship

78%

... equipped with four SE 400 L4 three-phase synchronous generators for energy supply, two AH 450 L6 three-phase ... LL4 + Type SE 400 L4 Number of units 4 Machine type generator / synchronous Degree of protection IP 44 Cooling ... 856 Rated voltage [V] 400 Rated frequency [Hz] 50 Shaft height [mm] 400 Mounting IM B25 + Type AH 450 L6 ... 1.260 Rated voltage [V] 600 Rated frequency [Hz] 60

Size: 23 K - Created: 19-02-13 - Modified: 12-09-16 11:30
Path: /References/Ship & Offshore/Weser Pilot Station Ship

Furkelbach power plant, Italy

78%

... of Olang and 20% private. Thanks to the combination of Pelton turbines and an AEM synchronous generator, it is possible to feed over 2 GWh into the local network for this purpose each year. The ... 8 to 10 years. Technical data . SE 450 S6 + Type SE 450 S6 Number of units 1 Machine type generator / synchronous Degree of protection IP 44 Cooling system IC 81W Rated speed [rpm] 1.000 Rated ...

Size: 18.7 K - Created: 06-09-13 - Modified: 12-09-16 13:45
Path: /References/Hydropower/Furkelbach power plant, Italy

Rukarara II power plant, Africa

77%

... of the Francis turbine inlets. The turbine set is directly coupled with two AEM synchronous generators. There was a worldwide invitation to tender for the hydropower project. The construction of ... own machines.  Technical data . SE 630 SB8 Type SE 630 SB8 Number of units 2 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated speed [rpm] 750 Rated ...

Size: 18.3 K - Created: 12-09-13 - Modified: 12-09-16 14:03
Path: /References/Hydropower/Rukarara II power plant, Africa

Sailing yacht A

77%

... electric motors are used as drives for the bow thrusters. However, they also run as shaft generators or in addition to the diesel engines in booster mode. Technical data . WH 400 L4 + Type WH ... Rated speed [rpm] 1,200 Rated power [kW] 650 Rated voltage [V] 690 Rated frequency [Hz] 40,2 Shaft heigth [mm] 400 Mounting IM V1 Quick Contact Tel.: +49 340 203-200 Fax: +49 340 203-311 ...

Size: 18.7 K - Created: 25-07-17 - Modified: 10-10-17 13:37
Path: /References/Ship & Offshore/Sailing yacht A

Eggenbach power plant, Austria

77%

... performance to be doubled to between 2.5 and 3 GWh per year. Technical data . SE 500 M10 + Type SE 500 M10 Number of units 1 Machine type generator / synchronous Degree of protection IP 21 Cooling system IC 01 Rated speed [rpm] 600 Rated power [kVA] 600 Rated voltage [V] 400 Rated frequency [Hz] 50

Size: 19.8 K - Created: 05-09-13 - Modified: 12-09-16 13:54
Path: /References/Hydropower/Eggenbach power plant, Austria

History

75%

... production methods”. 2001 17th August: the first generator leaves the factory with a shaft height of 710. 1995 First certification of the AEM ... power plant (Mecklenburg), two synchronous generators from Dessau are installed for electricity generation. These are not replaced by new AEM generators until 2005, for reasons relating to power rating. ...

Size: 28 K - Created: 07-05-12 - Modified: 18-07-17 15:44
Path: /Company/History

Converter units

75%

... Converter units Rotating frequency converters are machine units consisting of a motor and a generator. Unlike transformers, converter units are able to convert voltage and frequency thanks to the ... machines, or a combination of both. The combination of an asynchronous motor and synchronous generator is most common. Asynchronous drives are used mainly in the production of higher frequencies, ...

Size: 23 K - Created: 07-05-12 - Modified: 08-03-16 11:03
Path: /Products/Converter units

Sonne Deap sea research vessel

74%

... causes of environmental damage or new approaches in biotechnology. Technical data . SE 630 S6 + Type SE 630 S6 Number of units 4 Machine type generator / synchronous Degree of protection IP 44 Cooling system IC 81W Rated speed [rpm] 1,000 Rated power [kVA] 1,944 Rated voltage [V] 690 Rated frequency [Hz] 50 

Size: 19.0 K - Created: 02-10-13 - Modified: 12-09-16 13:06
Path: /References/Ship & Offshore/Sonne Deap sea research vessel

Manufacturing

70%

... total of €14 million in modernisation processes between 2006 and 2012. Meanwhile, motors and generators are constructed in single production in a production area that is approximately 11,000m² in ... CNC-controlled lathes permits the optimal production of a single unit. The multifunctional shaft machining centre allows for the complete machining of precise and complex workpieces and ...

Size: 27 K - Created: 07-05-12 - Modified: 17-09-15 08:48
Path: /Company/Manufacturing

History of origins

69%

... location. In 1953, the manufacture of self-excited synchronous generators was also added. Two synchronous generators from 1954 were still being used for power generation at the listed ... when they were replaced by new and much more powerful AEM SE 630 S16 generators. VEM-Antriebstechnik AG Dresden On 5/04/1990, following the German ... problems resulting from the partial transfer of products to larger

Size: 22 K - Created: 20-10-12 - Modified: 17-09-15 07:31
Path: /Company/History of origins

Quick Contact

Tel.:+49 340 203-200
Fax:+49 340 203-311
E-mail:info@aemdessau.de
Enquiry form
Contact partner